# Ruggedization

 
Level 1—Standard Air-Cooled
Level 3—Rugged Air-Cooled
Level 5—Conduction-Cooled
Operating Temperature
0°C to +55°C ambient †Per MIL-STD-810F 501.4 Procedure II and Method 502.4 Procedure II
-40°C to +70°C ambient †Per MIL-STD-810F 501.4 Procedure II and Method 502.4 Procedure II
-40°C to +85°C board rail surface temperaturePer MIL-STD-810F Method 501.4 Procedure II and Method 502.4 Procedure II
Storage Temperature
-40°C to +85°C ambientPer MIL-STD-810F Method 501.4 Procedure I and Method 502.4 Procedure I
-55°C to +105°C ambientPer MIL-STD-810F Method 501.4 Procedure I and Method 502.4 Procedure I
-55°C to +105°C board rail surface temperaturePer MIL-STD-810F Method 501.4 Procedure I and Method 502.4 Procedure I
Vibration
0.002 g²/Hz (maximum), 1 hour per axis from 5 to 2000 HzPer MIL-STD-810F Method 514.5 Procedure I ‡
0.04 g²/Hz (maximum), 1 hour per axis from 5 to 2000 HzPer MIL-STD-810F Method 514.5 Procedure I ‡
0.1 g²/Hz (maximum), 1 hour per axis from 5 to 2000 HzPer MIL-STD-810F Method 514.5 Procedure I ‡
Shock
20 g, 11 ms sawtoothPer MIL-STD-810F Method 516.5 Procedure I
30 g, 11 ms sawtoothPer MIL-STD-810F Method 516.5 Procedure I
40 g, 11 ms sawtoothPer MIL-STD-810F Method 516.5 Procedure I
Humidity
Up to 95% non-condensingPer MIL-STD-810F Method 507.4
Up to 95% non-condensingPer MIL-STD-810F Method 507.4
Up to 95% non-condensingPer MIL-STD-810F Method 507.4
Application Notes
For standard commercial applications.
† Contact factory for air flow rate details.
‡ 5-1000 Hz, PSD 0.002 g2/Hz; 1000-2000 Hz, PSD decreasing at 6 dB/octave.
For applications requiring an extended thermal range as well as increased shock and vibration requirements. Note: Level 3 ruggedization requires special consideration at the system level. Contact X-ES to discuss specific environmental requirements for rugged air-cooled products.
† Contact factory for air flow rate details.
‡ 5-100 Hz, PSD increasing at 3 dB/octave; 100-1000 Hz, PSD 0.04 g²/Hz; 1000-2000 Hz, PSD decreasing at 6 dB/octave
For rugged applications requiring an extended environmental range and conduction cooling.
‡ 5-100 Hz, PSD increasing at 3 dB/octave; 100-1000 Hz, PSD 0.1 g²/Hz; 1000-2000 Hz, PSD decreasing at 6 dB/octave